Density Profile and Fluctuation Measurements by Microwave Reflectometry on EAST

Journal

PLASMA SCIENCE & TECHNOLOGY
Volume 16, Issue 4, Pages 311-315

Publisher

IOP PUBLISHING LTD
DOI: 10.1088/1009-0630/16/4/02

Keywords

microwave reflectometry; pedestal; density fluctuation; EAST

Funding

  1. National Natural Science Foundation of China [11305208, 11275234]
  2. National Magnetic Confinement Fusion Program of China [2014CB106000, 2014GB106003]

Ask authors/readers for more resources

A microwave reflectometry system operating in the V-band frequency with extraordinary mode polarization has been developed on the EAST tokamak. The reflectometry system, using a voltage-controlled oscillator (VCO) source driven by an arbitrary waveform generator with high temporal resolution, can operate for the density profile measurement. The result of the bench test shows that the output frequency of the VCO has a linear dependence on time. The dispersion of reflectometry system is determined and reported in this paper. The evolution of a pedestal density profile during the L-H transition is observed by the reflectometry in H-mode discharges on EAST tokamak. A frequency synthesizer is used to replace the VCO as microwave source for density fluctuation measurements. The level of density fluctuation in the pedestal shows an abrupt decrease when the plasma enters into H-mode. A coherent mode with a frequency of about 100 kHz is observed and the mode frequency decreases gradually as the pedestal evolves.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available