4.5 Article

In vivo electrical conductivity imaging of a canine brain using a 3 T MREIT system

Journal

PHYSIOLOGICAL MEASUREMENT
Volume 29, Issue 10, Pages 1145-1155

Publisher

IOP PUBLISHING LTD
DOI: 10.1088/0967-3334/29/10/001

Keywords

in vivo; MREIT; conductivity image; canine brain

Funding

  1. SRC/ERC [R11-2002-103]
  2. MOST/KICOS [M60501000035-05A0100-03510]
  3. Ministry of Health and Welfare [02-PJ3-PG6-EV07-0002]
  4. Korea Health Promotion Institute [A020607] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  5. National Research Foundation of Korea [R11-2002-103-05002-0, 과06A1304, 핵06A2701, R11-2002-103-07001-0, R11-2002-103-09003-0, R11-2002-103-09001-0, mostR11-2002-103-00000-0, R11-2002-103-08002-0] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

Magnetic resonance electrical impedance tomography (MREIT) aims at producing high-resolution cross-sectional conductivity images of an electrically conducting object such as the human body. Following numerous phantom imaging experiments, the most recent study demonstrated successful conductivity image reconstructions of postmortem canine brains using a 3 T MREIT system with 40 mA imaging currents. Here, we report the results of in vivo animal imaging experiments using 5 mA imaging currents. To investigate any change of electrical conductivity due to brain ischemia, canine brains having a regional ischemic model were scanned along with separate scans of canine brains having no disease model. Reconstructed multi-slice conductivity images of in vivo canine brains with a pixel size of 1.4mmshowed a clear contrast between white and gray matter and also between normal and ischemic regions. We found that the conductivity value of an ischemic region decreased by about 10-14%. In a postmortem brain, conductivity values of white and gray matter decreased by about 4-8% compared to those in a live brain. Accumulating more experience of in vivo animal imaging experiments, we plan to move to human experiments. One of the important goals of our future work is the reduction of the imaging current to a level that a human subject can tolerate. The ability to acquire high-resolution conductivity images will find numerous clinical applications not supported by other medical imaging modalities. Potential applications in biology, chemistry and material science are also expected.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available