4.7 Article

Sensitivity of Rapid Influenza Diagnostic Testing for Swine-Origin 2009 A (H1N1) Influenza Virus in Children

Journal

PEDIATRICS
Volume 125, Issue 3, Pages E639-E644

Publisher

AMER ACAD PEDIATRICS
DOI: 10.1542/peds.2009-2669

Keywords

influenza; sensitivity and specificity; rapid influenza diagnostic test

Categories

Funding

  1. Canadian Institutes of Health Research/SickKids Foundation [XG08-049R]
  2. Canadian Institutes of Health Research [CAT86860]
  3. University of Toronto

Ask authors/readers for more resources

BACKGROUND: The rapidly evolving pandemic of novel 2009 swine-origin influenza A (H1N1) virus (S-OIV) demands that accurate and practical diagnostics be urgently evaluated for their potential clinical utility. OBJECTIVE: To determine the diagnostic accuracy of a rapid influenza diagnostic test (RIDT) and direct fluorescent antibody (DFA) assay for S-OIV by using reverse-transcription polymerase chain reaction (RTPCR) as the reference standard. METHODS: We prospectively recruited children (aged 0-17 years) assessed in the emergency department of a pediatric referral hospital and a community pediatric clinic for influenza-like illness between May 22 and July 25, 2009. RIDT (performed on-site) and DFA were compared with RT-PCR to determine their sensitivity and specificity for S-OIV. We also compared the sensitivity of RIDT for S-OIV to that for seasonal influenza over 2 preceding seasons. RESULTS: Of 820 children enrolled, 651 were from the emergency department and 169 were from the clinic. RIDT sensitivity was 62% (95% confidence interval [CI]: 52%-70%) for S-OIV, with a specificity of 99% (95% CI: 92%-100%). DFA sensitivity was 83% (95% CI: 75%-89%) and was superior to that of RIDT (P < .001). RIDT sensitivity for S-OIV was comparable to that for seasonal influenza when using DFA supplemented with culture as the reference standard. RIDT sensitivity for influenza viruses was significantly higher in children 5 years of age or younger (P = .003) and in patients presenting <= 2 days after symptom onset (P < .001). CONCLUSIONS: The sensitivity of RIDT for detection of S-OIV is higher than recently reported in mixed adult-pediatric populations but remains suboptimal. Pediatrics 2010; 125: e639-e644

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available