4.1 Article

Pediatric video laryngoscope versus direct laryngoscope: a meta-analysis of randomized controlled trials

Journal

PEDIATRIC ANESTHESIA
Volume 24, Issue 10, Pages 1056-1065

Publisher

WILEY
DOI: 10.1111/pan.12458

Keywords

intubation; laryngoscope; video; pediatric; meta-analysis; quality effects

Funding

  1. National Natural Science Foundation of China [81201021]

Ask authors/readers for more resources

Background: We reviewed the updated literature and performed a meta-analysis based on randomized controlled trials in children to compare the clinical efficacy between video laryngoscopes (VLs) and direct laryngoscopes (DLs). Methods: We searched articles published in English matching the key words 'video laryngoscope (including Airtraq, GlideScope, Storz, TruView, AWS, Bullard, McGrath)' AND 'direct laryngoscope' AND 'children (including pediatric, infant, neonate)' in PubMed, Ovid, Google Scholar, and the Cochrane Library databases. Only prospective randomized controlled trials (RCTs), which compared the use of VLs and DLs in children, were included. The relative risk (RR), weighted mean difference (WMD), and their corresponding 95% confidence interval (95% CI) were calculated using the quality effects model of the METAXL 1.3 software for outcome data. Results: Fourteen studies were included in this meta-analysis. Although VLs improved the glottis visualization in most children either with normal airways or with potentially difficult intubations, the time to intubation (TTI) was prolonged in comparison to DLs (WMD: 4.9 s; 95% CI: 2.6-7.1). Subgroup analysis showed the GlideScope (WMD: 5.2 s; 95% CI: 2.0-8.5), TruView (WMD: 5.1 s; 95% CI: 0.7-9.5), Storz (WMD: 6.4 s; 95% CI: 4.8-8.1), and Bullard (WMD: 37.5 s; 95% CI: 21.0-54.0) rather than Airtraq (WMD: 0.6 s; 95% CI: -7.7-8.9) prolonged TTI. Although the success rate of the first attempt (RR: 0.96; 95% CI: 0.92-1.00) and associated complications (RR: 1.11; 95% CI: 0.39-3.16) were similar in both groups, VLs were associated with a higher incidence of failure (RR: 6.70; 95% CI: 1.53-29.39). Conclusion: This meta-analysis demonstrates that although VLs improved glottis visualization in pediatric patients, this was at the expense of prolonged TTI and increased failures. However, further studies are needed to clarify the efficacy and safety of VLs in hands of nonexperts and in children with airway problems.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available