4.2 Article

Implications of Minimizing Trauma During Conventional Cochlear Implantation

Journal

OTOLOGY & NEUROTOLOGY
Volume 32, Issue 6, Pages 962-968

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MAO.0b013e3182204526

Keywords

Cochlear implant(s); Hearing preservation; Hearing conservation; Auditory stimulation

Funding

  1. NIDCD NIH HHS [R01 DC009404] Funding Source: Medline

Ask authors/readers for more resources

Objective: To describe the relationship between implantation-associated trauma and postoperative speech perception scores among adult and pediatric patients undergoing cochlear implantation using conventional length electrodes and minimally traumatic surgical techniques. Study Design: Retrospective chart review (2002-2010). Setting: Tertiary academic referral center. Patients: All subjects with significant preoperative low-frequency hearing (<= 70 dB HL at 250 Hz) who underwent cochlear implantation with a newer generation implant electrode (Nucleus Contour Advance, Advanced Bionics HR90K [1J and Helix], and Med El Sonata standard H array) were reviewed. Intervention(s): Preimplant and postimplant audiometric thresholds and speech recognition scores were recorded using the electronic medical record. Main Outcome Measure(s): Postimplantation pure tone threshold shifts were used as a surrogate measure for extent of intracochlear injury and correlated with postoperative speech perception scores. Results: Between 2002 and 2010, 703 cochlear implant (CI) operations were performed. Data from 126 implants were included in the analysis. The mean preoperative low-frequency pure-tone average was 55.4 dB HL. Hearing preservation was observed in 55% of patients. Patients with hearing preservation were found to have significantly higher postoperative speech perception performance in the CI-only condition than those who lost all residual hearing. Conclusion: Conservation of acoustic hearing after conventional length cochlear implantation is unpredictable but remains a realistic goal. The combination of improved technology and refined surgical technique may allow for conservation of some residual hearing in more than 50% of patients. Germane to the conventional length CI recipient with substantial hearing loss, minimizing trauma allows for improved speech perception in the electric condition. These findings support the use of minimally traumatic techniques in all CI recipients, even those destined for electric-only stimulation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available