4.6 Article

The binary dissector: phase contrast tomography of two- and three-material objects from few projections

Journal

OPTICS EXPRESS
Volume 16, Issue 14, Pages 10736-10749

Publisher

OPTICAL SOC AMER
DOI: 10.1364/OE.16.010736

Keywords

-

Categories

Ask authors/readers for more resources

In X-ray computed tomography (CT) increased information requirements ( e. g. increased resolution) typically lead to a concurrent increase in the required number of viewing angles, scanning time and delivered dose. We demonstrate that using phase-contrast imaging it is possible to dissect two- and three-material objects into their component materials, which in combination with binary tomographic techniques allows us to satisfy increased information requirements without taking the usual images at additional viewing angles. This imaging scheme reduces the scanning time and dose delivered to samples by at least an order of magnitude when compared to conventional X-ray CT. The effects of noise on our reconstruction scheme are investigated for simulated data. Finally, a slice through a glass tube filled with silica and water is reconstructed from 18 projection images taken on an X-ray ultra Microscope (XuM). (C) 2008 Optical Society of America.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available