4.5 Article

Utility of multifrequency bioelectrical impedance compared with dual-energy x-ray absorptiometry for assessment of total and regional body composition varies between men and women

Journal

NUTRITION RESEARCH
Volume 32, Issue 7, Pages 479-485

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.nutres.2012.05.009

Keywords

Multifrequency bioelectrical impedance; Dual-energy x-ray absorptiometry; Body composition; Lean mass; Fat mass; Segmental lean mass

Funding

  1. Biospace, Inc
  2. USC Clinical Exercise Research Center

Ask authors/readers for more resources

Multifrequency bioelectrical impedance analysis of body composition may be an appropriate alternative to dual-energy x-ray absorptiometry. We hypothesized that there would be no significant differences between dual-energy x-ray absorptiometry and either the Biospace (Los Angeles, CA, USA) InBody 520 or 720 multifrequency bioelectrical impedance analysis devices for total lean body mass (LBM), appendicular lean mass (ALM), trunk lean mass (TM), and total fat mass (FM) in 25 men and 25 women (including lean, healthy, and obese individuals according to body mass index), age 18 to 49 years, weight of 73.6 +/- 15.4 kg. Both devices overestimated LBM in women (similar to 2.5 kg, P < .001) and underestimated ALM in men (similar to 3.0 kg, P < .05) and women (similar to 1.0 kg, P < .05). The 720 overestimated FM in men (1.6 kg, P < .05) and underestimated TM in women (0.6 kg, P <=.05). Regression analyses in men revealed R-2 (0.87-0.91), standard error of the estimate (SEE; 2.3-2.8 kg), and limits of agreement (LOAs; 4.5-5.7 kg) for LBM; R-2 (0.62-0.87), SEE (1.5-2.6 kg), and LOA (3.2-6.0 kg) for ALM; R-2 (0.52-0.71), SEE (2.4-3.0 kg), and LOA (4.6-6.1 kg) for TM; and R-2 (0.87-0.93), SEE (1.9-2.6 kg), and LOA (5.9-6.2 kg) for FM. Regression analyses in women revealed R-2 (0.87-0.88), SEE (1.8-1.9 kg), and LOA (4.1-4.2 kg) for LBM; R-2(0.78-0.79), SEE (1.4-1.5 kg), and LOA (2.7-2.9 kg) for ALM; R-2 (0.76-0.77), SEE (1.0 kg), and LOA (2.2-2.3 kg) for TM; and R-2 (0.95), SEE (2.2 kg), and LOA (4.3-4.4 kg) for FM. The InBody 520 and 720 are valid estimators of LBM and FM in men and of LBM, ALM, and FM in women; the 720 and 520 are valid estimators of TM in men and women, respectively. (C) 2012 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available