F-18-FDG-PET and MRI in patients with malignancies of the liver and pancreas Accuracy of retrospective multimodality image registration by using the CT-component of PET/CT

Journal

NUKLEARMEDIZIN-NUCLEAR MEDICINE
Volume 49, Issue 3, Pages 106-114

Publisher

GEORG THIEME VERLAG KG
DOI: 10.3413/nukmed-0263

Keywords

Magnetic resonance imaging; positron emission tomography; PET/MR; image fusion; multimodality imaging; PET/CT

Funding

  1. Bayer AG (Schweiz), Bayer Schering Pharma

Ask authors/readers for more resources

Purpose: To evaluate the accuracy of retrospective rigid image registration and fusion between F-18 fluorodeoxyglucose positron emission tomography (FOG-PET) and magnetic resonance imaging (MRI) of the upper abdomen. Patients, material, methods: Image fusion of PET and MRI was performed in 30 patients with suspected malignancy of the liver or pancreas. Using a commercially available image fusion tool capable of rigid manual point-based registration, PET-Images were retrospectively registered and fused by matching eight homologous points in the 3D spoiled gradient echo (GRE) MRI sequences acquired in portal venous phase and in the CT-component of PET/CT. Two separate observers (R1, R2) assessed accuracy of image registration by determining the distances in the x-, y- and z-axis as well as the absolute distance between anatomical landmarks which differed from the landmarks chosen for registration. Quality of fusion was graded using a three point grading scale (1 poorly fused; 2 satisfactory fused; 3 correctly fused) and compared to hybrid PET/CT fusion. Results: Mean time of registration per patient was less than 2 minutes. Objective registration assessment showed errors between 2.4-6.3 mm in x-axis: mean 3.6 mm (R1); 4.6 mm (R2), 2.3-9.3 mm in y-axis (mean 5.1 mm; 5.5 mm) and 3.3-12.0 mm in z-axis (mean 5.9 mm; 5.9 mm.) The mean error in absolute distance between points was 6.0-16.8 mm (mean 9.9 mm; 10.6 mm). In visual assessment, most fusions were graded to be satisfactory or correctly fused: R1, R2: grade 3, 11/30 (36.7%), 22/30 (73.3%); grade 2, 13/30 (43.3%), 8/30 (26.7%); grade 1, 6/30 (20%), 0/30 (0%). Fusions were mostly comparable to hybrid PET/CT fusions. All of the fusions were defined as diagnostically relevant by both observers. Conclusion: Retrospective rigid image fusion of FDG-PET and MRI of the upper abdomen using the CT-component of PET/CT for registration is feasible without adaptation in image acquisition protocols and shows sub-centimeter registration errors in most cases.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available