Journal
NUCLEAR MEDICINE COMMUNICATIONS
Volume 33, Issue 5, Pages 464-469Publisher
LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MNM.0b013e3283504543
Keywords
cadmium-zinc-telluride detectors; dosimetry; myocardial perfusion imaging; single-photon emission computed tomography thallium-201
Ask authors/readers for more resources
Objectives Thallium-201 is efficient for myocardial perfusion imaging, but leads to relatively high radiation exposure in patients. The purpose of this study was to compare the efficiency of low-dose thallium-201 imaging with cadmium-zinc-telluride (CZT) cameras with regular-dose thallium-201 imaging with conventional cameras. Methods We prospectively studied 137 consecutive patients referred for stress myocardial perfusion imaging who had previously had a myocardial single-photon emission computed tomography with thallium-201. We injected at stress a low dose of thallium-201 (1.1 MBq/kg, 28 mu Ci/kg), performed a 5-7 min scan with a CZT camera (GE DNM 530c), and assessed redistribution imaging when the initial images were abnormal. We compared the CZT scan with the conventional dual-head tomographic camera scan taken previously with a regular dose of thallium-201. Results The average delay between both scans was 22 months. The stress dose was 88 16 (2.38 +/- 0.43 mCi) versus 125 +/- 13 MBq (3.38 +/- 0.34 mCi; a 30% reduction). The time for camera acquisition was 6 versus 13 min (a 54% reduction). The myocardial counts were increased two-fold with CZT (mean: 446 Kcounts). The quality of CZT images was better in 69% of the cases. There were 59 artifacts with conventional cameras and 29 artifacts with CZT (P<0.01). The diagnostic agreement was calculated in patients without clinical or angiographic changes between both scans (115 patients) and was high (97%). The effective dose at stress was less than 12 mSv. High myocardial counting allowed for further decrease in the injected activity, leading to an effective dose as low as 8 mSv. Conclusion With reduced activities of thallium-201 and low effective doses, the CZT camera provides reliable, high-quality imaging. Nucl Med Commun 33:464-469 (C) 2012 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available