4.1 Article

Effects of different doses of radioactive iodine for remnant ablation on successful ablation and on long-term recurrences in patients with differentiated thyroid carcinoma

Journal

NUCLEAR MEDICINE COMMUNICATIONS
Volume 32, Issue 10, Pages 954-959

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MNM.0b013e32834956ec

Keywords

ablation success; differentiated thyroid carcinoma; radioiodine remnant ablation

Funding

  1. Ministry for Health, Welfare and Family Affairs, Republic of Korea [A084136]
  2. Korea Health Promotion Institute [A084136] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

Objectives The aim of this study was to compare ablation success and disease-free survival (DFS) on the basis of different ablation doses. Methods This retrospective study enrolled differentiated thyroid carcinoma patients who underwent total thyroidectomy and radioactive remnant ablation at the Asan Medical Center between January 2000 and December 2004. Radioactive iodine doses of 30 mCi (group A), 80 mCi (group B), and 150 mCi (group C) were administered according to the patients' risk of recurrences based on the clinicopathologic parameters at the time of surgery. Ablation success was defined as absence of abnormal uptake on diagnostic whole-body scan. Results Among 1024 patients, successful ablation was achieved in 81.7% in group A, in 89.5% in group B, and in 94.8% in group C (P<0.001). A total of 100 patients (9.8%) had clinical recurrences during 6.6 years of median follow-up. DFS was evaluated according to ablation success in each dose group. There were no significant differences in DFS. Side effects of radioactive iodine were negligible with dose up to 80 mCi; however, 2% of patients developed permanent salivary dysfunction in group C. Conclusion In cases of different ablation doses administered according to patients' risk of recurrences, we found that a higher dose of radioiodine was associated with a higher rate of ablation success compared with lower doses. However, successful ablation was not associated with a reduction in clinical recurrences. The optimal dose for ablation must be adjusted according to the risk group of individual patients to avoid unnecessary radiation and maximize therapeutic efficacy. Nucl Med Commun 32:954-959 (C) 2011 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins. Nuclear Medicine Communications 2011, 32:954-959

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available