4.4 Article

Radio Frequency Fragment Separator at NSCL

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.nima.2009.05.100

Keywords

Fragment Separator; Radio Frequency; Radioactive beam; Velocity filter

Funding

  1. National Science Foundation [PHY02-16783, PHY-06-06007]

Ask authors/readers for more resources

A new device has been designed and built at NSCL which provides additional filtering of radioactive beams produced via projectile fragmentation. The Radio Frequency Fragment Separator (RFFS) uses the time micro structure of the beams accelerated by the cyclotrons to deflect particles according to their time-of-flight, in effect producing a phase filtering. The transverse RF (Radio Frequency) electric field of the RFFS has superior filtering performance compared to other electrostatic devices, such as Wien filters. Such filtering is critical for radioactive beams produced on the neutron-deficient side of the valley of stability, where strong contamination occurs at intermediate energies from 50 to 200 MeV/u. (C) 2009 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-