4.7 Article

High temperature corrosion of thermally sprayed NiCr and FeCr coatings covered with a KCl-K2SO4 salt mixture

Journal

SURFACE & COATINGS TECHNOLOGY
Volume 265, Issue -, Pages 235-243

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.surfcoat.2014.11.012

Keywords

Thermal spray coaling; HVOF; Wire arc; Biomass; High temperature corrosion; Corrosion protection

Funding

  1. Tekes - the National Technology Agency of Finland

Ask authors/readers for more resources

Current boiler tube materials and designs are sensitive to changes in process conditions. The desire to increase efficiency through the increase in process temperature and the use of high-chlorine and alkali containing fuels such as biomass is challenging. The alloying of steel to increase the corrosion resistance leads to a significant increase in cost. Thermally sprayed coatings offer promising, effective, flexible and cost efficient solution to fulfil the material needs for the future. However, some heat exchanger design alterations have to be overcome before global commercialization. High temperature corrosion in combustion plants can occur by a variety of mechanisms, including passive scale degradation with subsequent rapid scaling, loss of adhesion and scale detachment, attack by molten or partly molten deposits via fluxing reactions and intergranular/interlamellar corrosion. The activated chlorine corrosion mechanism plays a key role in the thermally sprayed coatings due to their unique lamellar structure. In this study, the corrosion behaviour of NiCr and FeCr (HI/OF and wire arc) thermally sprayed coatings was tested under simplified biomass combustion conditions. The tests were carried out by using a KCl-K2SO4 salt mixture as a synthetic biomass ash, which was placed on the coated materials and then heat treated for one week (168 h) at two different temperatures (550 degrees C and 600 degrees C) and in two different gas atmospheres (air and air + 30% H2O). After exposure, the metallographic cross sections of the coatings were studied with SEM/EDX The results showed that the coatings behaved relatively well at the lower test temperature while critical interlamellar corrosion was observed in some cases at the higher test temperature. A few coatings (HI/OF Ni49Cr, HVOF Ni21Cr, and wire arc sprayed Fe30Cr) showed promising performance even at 600 degrees C in both atmospheres (dry and wet). (C), 2014 Published by Elsevier B.V.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available