4.8 Article

Strategies of Radioiodine Ablation in Patients with Low-Risk Thyroid Cancer

Journal

NEW ENGLAND JOURNAL OF MEDICINE
Volume 366, Issue 18, Pages 1663-1673

Publisher

MASSACHUSETTS MEDICAL SOC
DOI: 10.1056/NEJMoa1108586

Keywords

-

Funding

  1. French National Cancer Institute (INCa)
  2. French Ministry of Health
  3. Genzyme

Ask authors/readers for more resources

Background It is not clear whether the administration of radioiodine provides any benefit to patients with low-risk thyroid cancer after a complete surgical resection. The administration of the smallest possible amount of radioiodine would improve care. Methods In our randomized, phase 3 trial, we compared two thyrotropin-stimulation methods (thyroid hormone withdrawal and use of recombinant human thyrotropin) and two radioiodine (I-131) doses (i.e., administered activities) (1.1 GBq and 3.7 GBq) in a 2-by-2 design. Inclusion criteria were an age of 18 years or older; total thyroidectomy for differentiated thyroid carcinoma; tumor-node-metastasis (TNM) stage, ascertained on pathological examination (p) of a surgical specimen, of pT1 (with tumor diameter <= 1 cm) and N1 or Nx, pT1 (with tumor diameter >1 to 2 cm) and any N stage, or pT2N0; absence of distant metastasis; and no iodine contamination. Thyroid ablation was assessed 8 months after radioiodine administration by neck ultrasonography and measurement of recombinant human thyrotropin-stimulated thyroglobulin. Comparisons were based on an equivalence framework. Results There were 752 patients enrolled between 2007 and 2010; 92% had papillary cancer. There were no unexpected serious adverse events. In the 684 patients with data that could be evaluated, ultrasonography of the neck was normal in 652 (95%), and the stimulated thyroglobulin level was 1.0 ng per milliliter or less in 621 of the 652 patients (95%) without detectable thyroglobulin antibodies. Thyroid ablation was complete in 631 of the 684 patients (92%). The ablation rate was equivalent between the I-131 doses and between the thyrotropin-stimulation methods. Conclusions The use of recombinant human thyrotropin and low-dose (1.1 GBq) postoperative radioiodine ablation may be sufficient for the management of low-risk thyroid cancer. (Funded by the French National Cancer Institute [INCa] and the French Ministry of Health; ClinicalTrials.gov number, NCT00435851; INCa number, RECF0447.)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available