Journal
NEW ENGLAND JOURNAL OF MEDICINE
Volume 361, Issue 19, Pages 1827-1837Publisher
MASSACHUSETTS MEDICAL SOC
DOI: 10.1056/NEJMoa0902905
Keywords
-
Categories
Funding
- Cooperative Studies Program of the Department of Veterans Affairs (VA) Office of Research and Development
- VA Central Office, Office of Patient Care Services
- Offices of Research and Development at the Eastern Colorado Health Care System VA Medical Center, Denver
- Northport VA Medical Center, Northport, NY.
Ask authors/readers for more resources
Background: Coronary-artery bypass grafting (CABG) has traditionally been performed with the use of cardiopulmonary bypass (on-pump CABG). CABG without cardiopulmonary bypass (off-pump CABG) might reduce the number of complications related to the heart-lung machine. Methods: We randomly assigned 2203 patients scheduled for urgent or elective CABG to either on-pump or off-pump procedures. The primary short-term end point was a composite of death or complications (reoperation, new mechanical support, cardiac arrest, coma, stroke, or renal failure) before discharge or within 30 days after surgery. The primary long-term end point was a composite of death from any cause, a repeat revascularization procedure, or a nonfatal myocardial infarction within 1 year after surgery. Secondary end points included the completeness of revascularization, graft patency at 1 year, neuropsychological outcomes, and the use of major resources. Results: There was no significant difference between off-pump and on-pump CABG in the rate of the 30-day composite outcome (7.0% and 5.6%, respectively; P=0.19). The rate of the 1-year composite outcome was higher for off-pump than for on-pump CABG (9.9% vs. 7.4%, P=0.04). The proportion of patients with fewer grafts completed than originally planned was higher with off-pump CABG than with on-pump CABG (17.8% vs. 11.1%, P<0.001). Follow-up angiograms in 1371 patients who underwent 4093 grafts revealed that the overall rate of graft patency was lower in the off-pump group than in the on-pump group (82.6% vs. 87.8%, P<0.01). There were no treatment-based differences in neuropsychological outcomes or short-term use of major resources. Conclusions: At 1 year of follow-up, patients in the off-pump group had worse composite outcomes and poorer graft patency than did patients in the on-pump group. No significant differences between the techniques were found in neuropsychological outcomes or use of major resources. (ClinicalTrials.gov number, NCT00032630.) N Engl J Med 2009;361:1827-37.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available