4.7 Article

Postmortem verification of MS cortical lesion detection with 3D DIR

Journal

NEUROLOGY
Volume 78, Issue 5, Pages 302-308

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1212/WNL.0b013e31824528a0

Keywords

-

Funding

  1. Dutch MS Research Foundation (Voorschoten, the Netherlands) [09-358d]
  2. Dutch MS Research Foundation
  3. MS Research Foundation
  4. Actelion Pharmaceuticals Ltd
  5. Biogen Idec
  6. Bayer Schering Pharma
  7. GlaxoSmithKline
  8. Teva Pharmaceutical Industries Ltd.
  9. Merck Serono
  10. Novartis
  11. UCB
  12. Roche
  13. European Community Brussels
  14. MS Research Foundation Netherlands

Ask authors/readers for more resources

Objective: To assess the sensitivity and specificity of 3D double inversion recovery (DIR) MRI for detecting multiple sclerosis (MS) cortical lesions (CLs) using a direct postmortem MRI to histopathology comparison. Methods: Single-slab 3D DIR and 3D fluid-attenuated inversion recovery (FLAIR) images of 56 matched fresh brain samples from 14 patients with chronic MS were acquired at 1.5 T. The images of both sequences were prospectively scored for CLs in consensus by 3 experienced raters who were blinded to histopathology and clinical data. Next, CLs were identified histopathologically and were scored again on 3D DIR and 3D FLAIR (retrospective scoring). CLs were classified as intracortical or mixed gray matter (GM)-white matter lesions. Deep GM lesions were also scored. False-positive scores were noted and, from this, specificity was calculated. Results: We found a sensitivity for 3D DIR to detect MS CLs of 18%, which is 1.6-fold higher than 3D FLAIR (improves to 37% with retrospective scoring; 2.0-fold higher than 3D FLAIR). We detected mixed GM-white matter lesions with a sensitivity of 83% using 3D DIR (65% sensitivity for 3D FLAIR), which improved to 96% upon retrospective scoring (91% for 3D FLAIR). For purely intracortical lesions, 3D DIR detected more than 2-fold more than 3D FLAIR (improved to >3-fold upon retrospective scoring). The specificity of 3D DIR to MS CLs was found to be 90%. Conclusions: In this postmortem verification study, we have shown that 3D DIR is highly pathologically specific, and more sensitive to CLs than 3D FLAIR in MS. Neurology (R) 2012;78:302-308

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available