4.7 Article

Development of a magnetic sensor for detection and sizing of internal pipeline corrosion defects

Journal

NDT & E INTERNATIONAL
Volume 42, Issue 8, Pages 669-677

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.ndteint.2009.06.009

Keywords

Inspection; Pipelines; Magnetic sensor; Internal corrosion; Sensor for thick walls

Ask authors/readers for more resources

Magnetic flux leakage (MFL) is the most used technique for pipeline inspection, being applied through the use of instrumented PIGs. The pipe wall is magnetized and when metal loss or other irregularities occur, a larger fraction of the magnetic flux leaks outwards from the wall and is detected by sensors. MFL presents some limitations since it requires magnetic saturation of the pipe wall. Therefore, it is difficult to inspect small diameter and thick wall pipelines. Internal corrosion sensor (ICS) has been developed as a solution for internal corrosion measurements of thick walls. The technique, also called field disturbance, is based in a direct magnetic response from a small area of the wall. It is not necessary to achieve the magnetic saturation of the pipe material, and thus ICS performance is not affected by the thickness of the pipe wall. In the present work, finite element calculations are performed and the best resultant configuration of the sensor is proposed. Experimental tests with a prototype were carried out and the results give a strong indication of the validity of the theoretical model proposed for sizing. (C) 2009 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available