4.6 Article

Microwave surface impedance measurements on reduced graphene oxide

Journal

NANOTECHNOLOGY
Volume 23, Issue 28, Pages -

Publisher

IOP PUBLISHING LTD
DOI: 10.1088/0957-4484/23/28/285706

Keywords

-

Funding

  1. UK NMO EMT

Ask authors/readers for more resources

Here we report a non-contact method for microwave surface impedance measurements of reduced graphene oxide samples using a high Q dielectric resonator perturbation technique, with the aim of studying the water content of graphene oxide flakes. Measurements are made before, during and after heating and cooling cycles. We have modelled plane wave propagation of microwaves perpendicular to the surface of graphene on quartz substrates, capacitively coupled to a dielectric resonator. Analytical solutions are derived for both changes in resonant frequency and microwave loss for a range of water layer thicknesses. In this way we have measured the presence of adsorbed water layers in reduced graphene oxide films. The water can be removed by low temperature annealing on both single and multilayer samples. The results indicate that water is intercalated between the layers in a multilayer sample, rather than only being adsorbed on the outer surfaces, and it can be released by applying a mild heating.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available