4.8 Article

Microstructural and electrochemical impedance characterization of bio-functionalized ultrafine ZnS nanocrystals-reduced graphene oxide hybrid for immunosensor applications

Journal

NANOSCALE
Volume 5, Issue 21, Pages 10494-10503

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/c3nr02575f

Keywords

-

Funding

  1. Council of Scientific and Industrial Research, India

Ask authors/readers for more resources

We report a mercaptopropionic acid capped ZnS nanocrystals decorated reduced graphene oxide (RGO) hybrid film on a silane modified indium-tin-oxide glass plate, as a bioelectrode for the quantitative detection of human cardiac myoglobin (Ag-cMb). The ZnS nanocrystals were anchored over electrochemically reduced GO sheets through a cross linker, 1-pyrenemethylamine hydrochloride, by carbodiimide reaction and have been characterized by scanning electron microscopy, transmission electron microscopy and energy dispersive X-ray spectroscopy. The transmission electron microscopic characterization of the ZnS-RGO hybrid shows the uniform distribution of ultra-fine nanoparticles of ZnS in nano-sheets of GO throughout the material. The protein antibody, Ab-cMb, was covalently linked to ZnS-RGO nanocomposite hybrid for the fabrication of the bioelectrode. A detailed electrochemical immunosensing study has been carried out on the bioelectrode towards the detection of target Ag-cMb. The optimal fitted equivalent circuit model that matches the impedance response has been studied to delineate the biocompatibility, sensitivity and selectivity of the bioelectrode. The bioelectrode exhibited a linear electrochemical impedance response to Ag-cMb in a range of 10 ng to 1 mu g mL(-1) in PBS (pH 7.4) with a sensitivity of 177.56 Omega cm(2) per decade. The combined synergistic effects of the high surface-to-volume ratio of ZnS(MPA) nanocrystals and conducting RGO has provided a dominant charge transfer characteristic (R-et) at the lower frequency region of < 10 Hz showing a good biocompatibility and enhanced impedance sensitivity towards target Ag-cMb. The impedance response sensitivity of the ZnS-RGO hybrid bioelectrode towards Ag-cMb has been found to be about 2.5 fold higher than that of a bare RGO modified bioelectrode.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available