4.6 Article

Enhanced Sensitivity of Gas Sensor Based on Poly(3-hexylthiophene) Thin-Film Transistors for Disease Diagnosis and Environment Monitoring

Journal

SENSORS
Volume 15, Issue 4, Pages 9592-9609

Publisher

MDPI
DOI: 10.3390/s150409592

Keywords

-

Funding

  1. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES-MES-Cuba) [134/11]
  2. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico [MCT/CNPq/CT-INFO 17/2009, 142302/2010-4]
  3. Fundacao de Amparo a Pesquisa do Estado de Sao Paulo [FAPESP 08/57706-4, 09/05589-7, 11/17184-1, 13/19420-0]
  4. Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP) [08/57706-4, 11/17184-1, 13/19420-0, 09/05589-7] Funding Source: FAPESP

Ask authors/readers for more resources

Electronic devices based on organic thin-film transistors (OTFT) have the potential to supply the demand for portable and low-cost gadgets, mainly as sensors for in situ disease diagnosis and environment monitoring. For that reason, poly(3-hexylthiophene) (P3HT) as the active layer in the widely-used bottom-gate/bottom-contact OTFT structure was deposited over highly-doped silicon substrates covered with thermally-grown oxide to detect vapor-phase compounds. A ten-fold organochloride and ammonia sensitivity compared to bare sensors corroborated the application of this semiconducting polymer in sensors. Furthermore, P3HT TFTs presented approximately three-order higher normalized sensitivity than any chemical sensor addressed herein. The results demonstrate that while TFTs respond linearly at the lowest concentration values herein, chemical sensors present such an operating regime mostly above 2000 ppm. Simultaneous alteration of charge carrier mobility and threshold voltage is responsible for pushing the detection limit down to units of ppm of ammonia, as well as tens of ppm of alcohol or ketones. Nevertheless, P3HT transistors and chemical sensors could compose an electronic nose operated at room temperature for a wide range concentration evaluation (1-10,000 ppm) of gaseous analytes. Targeted analytes include not only biomarkers for diseases, such as uremia, cirrhosis, lung cancer and diabetes, but also gases for environment monitoring in food, cosmetic and microelectronics industries.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available