Journal
MUSCLE & NERVE
Volume 46, Issue 6, Pages 871-878Publisher
WILEY
DOI: 10.1002/mus.23426
Keywords
carpal tunnel syndrome; median nerve; screening; sensitivity; ultrasound
Categories
Ask authors/readers for more resources
Introduction: Sonographically measured median nerve cross-sectional area (CSA) at the wrist is increased in patients with carpal tunnel syndrome (CTS). Ultrasound of the median nerve may be useful in screening for electrodiagnostic (EDx) abnormalities. Methods: EDx studies were performed on all participants. Sonographic evaluation of median nerve CSA at the wrist and in the forearm was performed by a physician blinded to the EDx results. Multivariate and receiver operating characteristic (ROC) analysis were used to assess the data. Results: Fifty control wrists and 192 symptomatic wrists were analyzed. Sensitivity of ultrasound in excluding EDx abnormality was 99% for CSA of 9 mm2 and 97% for a wristforearm ratio (WFR) of 1.4. There was no clinically significant correlation between ultrasound parameters and EDx severity. Conclusions: Median nerve ultrasound is a highly sensitive screening tool for EDx abnormality, but it cannot determine severity. This may lead to changes in the current standards for evaluating CTS. Muscle Nerve, 2012