4.4 Article

Evaluation of 89Zr-rituximab Tracer by Cerenkov Luminescence Imaging and Correlation with PET in a Humanized Transgenic Mouse Model to Image NHL

Journal

MOLECULAR IMAGING AND BIOLOGY
Volume 15, Issue 4, Pages 468-475

Publisher

SPRINGER
DOI: 10.1007/s11307-013-0624-0

Keywords

Cerenkov radiation; Immuno-CLI; Zr-89-rituximab; huCD20 imaging

Funding

  1. Small Animal Imaging Core
  2. Quantitation and Visualization Core
  3. National Cancer Institute [ICMIC P50CA114747]

Ask authors/readers for more resources

This research aimed to study the use of Cerenkov luminescence imaging (CLI) for non-Hodgkin's lymphoma (NHL) using Zr-89-rituximab positron emission tomography (PET) tracer with a humanized transgenic mouse model that expresses human CD20 and the correlation of CLI with PET. Zr-rituximab (2.6 MBq) was tail vein-injected into transgenic mice that express the human CD20 on their B cells (huCD20TM). One group (n = 3) received 2 mg/kg pre-dose (blocking) of cold rituximab 2 h prior to tracer; a second group (n = 3) had no pre-dose (non-blocking). CLI was performed using a cooled charge-coupled device optical imager. We also performed PET imaging and ex vivo studies in order to confirm the in vivo CLI results. At each time point (4, 24, 48, 72, and 96 h), two groups of mice were imaged in vivo and ex vivo with CLI and PET, and at 96 h, organs were measured by gamma counter. huCD20 transgenic mice injected with Zr-89-rituximab demonstrated a high-contrast CLI image compared to mice blocked with a cold dose. At various time points of 4-96 h post-radiotracer injection, the in vivo CLI signal intensity showed specific uptake in the spleen where B cells reside and, hence, the huCD20 biomarker is present at very high levels. The time-activity curve of dose decay-corrected CLI intensity and percent injected dose per gram of tissue of PET uptake in the spleen were increased over the time period (4-96 h). At 96 h, the Zr-89-rituximab uptake ratio (non-blocking vs blocking) counted (mean +/- standard deviation) for the spleen was 1.5 +/- 0.6 for CLI and 1.9 +/- 0.3 for PET. Furthermore, spleen uptake measurements (non-blocking and blocking of all time points) of CLI vs PET showed good correlation (R (2) = 0.85 and slope = 0.576), which also confirmed the corresponding correlations parameter value (R (2) = 0.834 and slope = 0.47) obtained for ex vivo measurements. CLI and PET of huCD20 transgenic mice injected with Zr-89-rituximab demonstrated that the tracer was able to target huCD20-expressing B cells. The in vivo and ex vivo tracer uptake corresponding to the CLI radiance intensity from the spleen is in good agreement with PET. In this report, we have validated the use of CLI with PET for NHL imaging in huCD20TM.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available