4.6 Article

Comparison of Four ActiGraph Accelerometers during Walking and Running

Journal

MEDICINE AND SCIENCE IN SPORTS AND EXERCISE
Volume 42, Issue 2, Pages 368-374

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1249/MSS.0b013e3181b3af49

Keywords

ACCELEROMETRY; ACTIVITY COUNTS; OBJECTIVE MONITORING; PHYSICAL ACTIVITY

Categories

Funding

  1. National Institutes of Health [R21CA122430]

Ask authors/readers for more resources

JOHN, D., B. TYO, and D. R. BASSETT. Comparison of Four ActiGraph Accelerometers during Walking and Running. Med. Sci. Sports Exerc., Vol. 42, No. 2, pp. 368-374 2010. Currently, researchers can use the ActiGraph 7164 or one of three different versions of the ActiGraph GT I M to objectively measure physical activity. Purpose: To determine whether differences exist between activity ;counts from the ActiGraph 7164 and the three versions of the GT1M at given walking and running speeds. Methods: Tell male participants (23.6 +/- 2.7 yr) completed treadmill walking and running at 10 different speeds (3-min stages) while wearing the ActiGraph 7164 and the latest GT1M (GT1M-V3) or the GT1M version one (GT1M-V1) and the GT1M version two (GT1M-V2). Participants walked at 3. 5, and 7 km.h(-1) followed by running at 8, 10 12 14, 16, 18, and 20 km.h(-1). The accelerometers were worn oil an elastic belt around the waist over the left and fight sides of the hip. Testing was performed on different days using a counterbalanced within-subjects design to account for potential differences attributable to accelerometer placement. At each speed, a one-way repeated-measures ANOVA was used to examine differences between activity counts in counts per minute (cpm). Post hoc pairwise comparisons with Bonferroni adjustments were used where appropriate. Results: There were no significant differences between activity counts at any given walking or running speed (P < 0.05). At all running speeds, activity counts from the ActiGraph 7164 and GT1M-V2 displayed the lowest and highest values, respectively. Output from all accelerometers peaked at 14 km.h(-1) (mean range = 8974 +/- 677 to 9412 +/- 982 cpm) and then gradually declined at higher speeds. The mean difference score at peak output between the ActiGraph as 7164 and GT1M-V2 was 439 565 cpm. Conclusions: There were no statistically significant differences between outputs from all the accelerometers, indicating that researchers can select any of the four ActiGraph accelerometers in doing research.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available