Volumetric HIFU ablation under 3D guidance of rapid MRI thermometry

Journal

MEDICAL PHYSICS
Volume 36, Issue 8, Pages 3521-3535

Publisher

AMER ASSOC PHYSICISTS MEDICINE AMER INST PHYSICS
DOI: 10.1118/1.3152112

Keywords

biomedical MRI; biothermics; muscle; thermometers

Funding

  1. Ligue Nationale Contre le Cancer (France)
  2. Conseil Regional d'Aquitaine (France)
  3. Philips Healthcare

Ask authors/readers for more resources

A volumetric sonication method is proposed that produces volume ablations by steering the focal point along a predetermined trajectory consisting of multiple concentric outward-moving circles. This method was tested in vivo on pig thigh muscle (32 ablations in nine animals). Trajectory diameters were 4, 12, and 16 mm with sonication duration depending on the trajectory size and ranging from 20 to 73 s. Despite the larger trajectories requiring more energy to reach necrosis within the desired volume, the ablated volume per unit applied energy increased with trajectory size, indicating improved treatment efficiency for larger trajectories. The higher amounts of energy required for the larger trajectories also increased the risk of off-focus heating, especially along the beam axis in the near field. To avoid related adverse effects, rapid volumetric multiplane MR thermometry was introduced for simultaneous monitoring of the temperature and thermal dose evolution along the beam axis and in the near field, as well as in the target region with a total coverage of six slices acquired every 3 s. An excellent correlation was observed between the thermal dose and both the nonperfused (R=0.929 for the diameter and R=0.964 for the length) and oedematous (R=0.913 for the diameter and R=0.939 for the length) volumes as seen in contrast-enhanced T(1)-weighted difference images and T(2)-weighted postsonication images, respectively. Histology confirmed the presence of a homogeneous necrosis inside the heated volumes. These results show that volumetric high-intensity focused ultrasound (HIFU) sonication allows for efficiently creating large thermal lesions while reducing treatment duration and also that the rapid multiplane MR thermometry improves the safety of the therapeutic procedure by monitoring temperature evolution both inside as well as outside the targeted volume.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available