4.4 Article

Validation of three-dimensional model-based tibio-femoral tracking during running

Journal

MEDICAL ENGINEERING & PHYSICS
Volume 31, Issue 1, Pages 10-16

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.medengphy.2008.03.003

Keywords

Kinematics; Accuracy; Knee; Image registration; X-ray; RSA

Funding

  1. National Institutes of Health [AR46387]

Ask authors/readers for more resources

The purpose of this study was to determine the accuracy of a radiographic model-based tracking technique that measures the three-dimensional in vivo motion of the tibio-femoral joint during running. Tantalum beads were implanted into the femur and tibia of three subjects and computed tomography (CT) scans were acquired after bead implantation. The subjects ran 2.5 m/s on a treadmill positioned within a biplane radiographic system while images were acquired at 250 frames per second. Three-dimensional implanted bead locations were determined and used as a gold standard to measure the accuracy of the model-based tracking. The model-based tracking technique optimized the correlation between the radiographs acquired via the biplane X-ray system and digitally reconstructed radiographs created from the volume-rendered CT model. Accuracy was defined in terms of measurement system bias, precision and root-mean-squared (rms) error. Results were reported in terms of individual bone tracking and in terms of clinically relevant tibio-femoral joint translations and rotations (joint kinematics). Accuracy for joint kinematics was as follows: model-based tracking measured static joint orientation with a precision of 0.2 degrees or better, and static joint position with a precision of 0.2 mm or better. Model-based tracking precision for dynamic joint rotation was 0.9 +/- 0.3 degrees, 0.6 +/- 0.3 degrees, and 0.3 +/- 0.1 degrees for flexion-extension, external-internal rotation, and ab-adduction, respectively. Model-based tracking precision when measuring dynamic joint translation was 0.3 +/- 0.1 mm, 0.4 +/- 0.2 mm, and 0.7 +/- 0.2 mm in the medial-lateral, proximal-distal, and anterior-posterior direction, respectively. The combination of high-speed biplane radiography and volumetric model-based tracking achieves excellent accuracy during in vivo, dynamic knee motion without the necessity for invasive bead implantation. (C) 2008 IPEM. Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available