4.3 Article

Spectral and Angular Responses of Surface Plasmon Resonance Based on the Kretschmann Prism Configuration

Journal

MATERIALS TRANSACTIONS
Volume 51, Issue 6, Pages 1150-1155

Publisher

JAPAN INST METALS
DOI: 10.2320/matertrans.M2010003

Keywords

Kretschmann surface plasmon resonance (SPR) sensor; characteristic transmission matrix (CTM) method; full width at half maximum (FWHM); phase shift; enhancement of magnetic field intensity

Funding

  1. Chung-Ang University
  2. National Research Foundation of Korea [핵C6A1108] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

The present study investigates the optical characteristics and the spectral and angular responses of a Kretschmann surface plasmon resonance (SPR) sensor configuration that is widely used in biological and chemical sensing applications In older to examine the influence of wave interference and optical properties of thin films on angular variation of reflectance at different incident angles, the Kretschmann SPR configurations made of gold films with 30, 52, and 70 nut thicknesses were fabricated and the reflectance was detected using a 633 not He-Ne laser. theta-2 theta rotation stages, and a silicon pin photo-detector In particular. this study involved the numerical analysis of angular and spectral variation of reflectance estimated using the characteristic transmission matrix (CTM) method It was found that the SPR sensitivity became highly dependent on the gold film thickness, indicating that in the thinner gold film case, the reflectance was recovered slowly after the SPR angle. whereas as the gold film thickness increased, the magnitude difference between the maximum and the minimum reflectance measured near the SIR angle was smaller than in other cases From the numerical analysis. it was shown that the phase shift is the most sensitive physical parameter for SPR sensor by comparing estimated FWHM values of reflectance, phase shift, and enhancement of magnetic field intensity Therefore. it was concluded that an appropriate metal thickness of around 50 nm was found for higher sensitivity [doi 10.2320/matertrans.M2010003]

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available