4.7 Article

Hydrogen induced cracking susceptibility of API 5L X70 pipeline steel in relation to microstructure and crystallographic texture developed after different thermomechanical treatments

Journal

MATERIALS CHARACTERIZATION
Volume 145, Issue -, Pages 142-156

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.matchar.2018.08.034

Keywords

Pipeline steel; Inclusion; Crystallographic texture; Microstructure; Hydrogen induced crack (HIC); Thermomechanically controlled processing (TMCP)

Funding

  1. Natural Sciences and Engineering Research Council of Canada (NSERC) [470033]

Ask authors/readers for more resources

Thermomechanical treatments offer an innovative means of controlling microstructure development and improving resistance to hydrogen induced cracking (HIC) in pipeline steel. This study was conducted on two X70 pipeline steels (labelled WG and WH) of the same chemical composition, but processed with different thermomechanical parameters. Specimen WG was hot rolled at a higher temperature range of 880-820 degrees C, while specimen WH was hot rolled between 830 and 760 degrees C before cooling at a rate of 25 degrees C/s. Early onset of HIC was observed in specimen WH after electrochemical hydrogen charging for 12 h in a solution of 0.2 M H2SO4 and 3 g/1 NH4SCN, without any applied stress. Also, test pieces from the surface and mid-thickness layers of each pipeline steel were subjected to slow strain rate tensile (SSRT) test with in-situ hydrogen charging. Characterization techniques such as Optical Microscopy, Scanning Electron Microscopy, Electron Backscattered Diffraction and Xray Diffraction were used to investigate the structure pipeline steel specimens. The role of inclusions on HIC was studied by Energy Dispersive X-ray Spectroscopy. Although the microstructure of both specimens were predominantly ferritic, more martensite/retained austenite (M/A) constituents featured in WG. Further crystallographic texture analysis indicates that grain orientation at the surfaces of both test specimens were similar with deviations towards <111> on the inverse pole figure (IPF); whereas, pole intensity at the mid-thickness deviated towards the <001> direction. Considering the increased fraction of banded-deformed grains with high stored energy, the lower HIC resistance of specimen WH in comparison to specimen WG was justified.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available