4.7 Article

In situ Raman spectroscopy investigation of bioactive glass reactivity: Simulated body fluid solution vs TRIS-buffered solution

Journal

MATERIALS CHARACTERIZATION
Volume 62, Issue 10, Pages 1021-1028

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.matchar.2011.07.008

Keywords

Raman spectroscopy; Bioactive glasses; Simulated body fluid; TRIS-buffered solution; Hydroxyl-carbonate apatite

Ask authors/readers for more resources

In the present contribution, the innovative in situ Raman micro-spectroscopy was applied to investigate the in vitro reactivity of various bioactive glasses. All the investigated glasses belonged to the Na(2)O\K(2)O-CaO-P(2)O(5)-SiO(2) system, but contained sensibly different percentages of network modifiers. The glasses were immersed for increasing times, up to 96 h, in simulated body fluid (SBF) and in tris-buffered (TRIS) solution. In this way, two fundamental items were addressed, i.e. the effect of the glass composition and the nature of the soaking fluid on the overall reactivity. As regards the SBF, all the glasses were able to promote the formation of a hydroxyl-carbonate apatite (HCA) surface layer in very short times. The reaction rate was particularly quick for the 45S5 Bioglass (R) and for its potassium-based variant (BioK), however all the glasses could form a continuous HCA layer already after 96 h. The observed difference in reaction kinetics may be due to the glass composition, since the glasses relatively poor in Na ions (BG_Ca) experience slower ion release in the first stages of the HCA formation, while the glasses relatively poor in Ca ions (BG_Na) undergo slower nucleation and growth of HCA. The development of HCA was also observed in TRIS, but the reaction rate was generally slower than in SBF. In fact, while the SBF is a complicated solution supersaturated in apatite, which favours the precipitation of HCA, the TRIS is a simple tris(hydroxymethyl)aminomethane solution in water, which does not provide the ions for the HCA formation. As a consequence, the aforementioned effects due to the glass composition were even more evident in TRIS than in SBF. Nevertheless the TRIS could represent a valuable alternative to the standard SBF whenever a slow reaction rate might be beneficial, such as, for example, in order to better observe the samples evolution. (C) 2011 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available