Journal
REMOTE SENSING OF ENVIRONMENT
Volume 157, Issue -, Pages 158-169Publisher
ELSEVIER SCIENCE INC
DOI: 10.1016/j.rse.2014.07.024
Keywords
MERIS; Chlorophyll-a; Inland waters; Validation; Lake Balaton; Algorithm
Funding
- GIONET
- European Commission [PITN-GA-2010-264509]
- UK NERC [NE/J024279/1]
- Fonds de recherche du Quebec - Nature et technologies
- Royal Society Wolfson Research Merit Award [2011/R3]
- NERC [nceo020005, fsf010001] Funding Source: UKRI
- Natural Environment Research Council [nceo020005] Funding Source: researchfish
Ask authors/readers for more resources
The 10-year archive of MEdium Resolution Imaging Spectrometer (MERIS) data is an invaluable resource for studies on lake system dynamics at regional and global scales. MERIS data are no longer actively acquired but their capacity for global scale monitoring of lakes from satellites will soon be re-established through the forthcoming Sentinel-3 Ocean and Land Colour Instrument (OLCI). The development and validation of in-water algorithms for the accurate retrieval of biogeochemical parameters is thus of key importance if the potential of MERIS and OLCI data is to be fully exploited for lake monitoring. This study presents the first extensive validation of algorithms for chlorophyll-a (chl-a) retrieval by MERIS in the highly turbid and productive waters of Lake Balaton, Hungary. Six algorithms for chl-a retrieval from MERIS over optically complex Case 2 waters, including band-difference and neural network architectures, were compared using the MERIS archive for 2007-2012. The algorithms were locally-tuned and validated using in situ chl-a data (n = 289) spanning the five year processed image time series and from all four lake basins. In general, both band-difference algorithms tested (Fluorescence Line Height (FLH) and Maximum Chlorophyll Index (MCI)) performed well, whereas the neural network processors were generally found to much less accurately-retrieve in situ chl-a concentrations. The Level 1b FLH algorithm performed best overall in terms of chl-a retrieval (R-2 = 0.87; RMSE = 4.19 mg m(-3); relative RMSE = 30.75%) and particularly at chl-a concentrations of >= 10 mg m(-3) (R-2 = 0.85; RMSE = 4.81 mg m(-3); relative RMSE = 20.77%). However, under mesotrophic conditions (i.e., chl-a < 10 mg m(-3)) FLH was outperformed by the locally-tuned FUB/WeW processor (relative FLH RMSE < 10 mg m(-3) = 57.57% versus relative FUB/WeW RMSE < 10 mg m(-3) = 46.96%). An ensemble selection of in-water algorithms is demonstrated to improve chl-a retrievals. (C) 2014 The Authors. Published by Elsevier Inc.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available