4.4 Article

Tissue gadolinium deposition in renally impaired rats exposed to different gadolinium-based MRI contrast agents: Evaluation with inductively coupled plasma mass spectrometry (ICP-MS)

Journal

MAGNETIC RESONANCE IMAGING
Volume 31, Issue 8, Pages 1412-1417

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.mri.2013.03.025

Keywords

Nephrogenic systemic fibrosis (NSF); Gd-EOB-DTPA; Gd-DTPA-BMA; Gd-HP-DO3A; Gadolinium (Gd)-based contrast agents (GBCAs); Inductively coupled plasma mass spectrometry (ICP-MS)

Funding

  1. japan Society for the Promotion of Science [23791458]
  2. Kawasaki Medical School Project [22-A37, 23-61]
  3. Grants-in-Aid for Scientific Research [23791458] Funding Source: KAKEN

Ask authors/readers for more resources

Objectives: To quantify tissue gadolinium (Gd) deposition in renally impaired rats exposed to Gd-EOB-DTPA and other Gd-based MRI contrast agents by means of inductively coupled plasma mass spectrometry (ICP-MS), and to compare the differences in distribution among major organs as possible triggers for nephrogenic systemic fibrosis (NSF). Methods: A total of 15 renally impaired rats were injected with Gd-EOB-DTPA, Gd-DTPA-BMA and Gd-HP-DO3A. Gd contents of skin, liver, kidney, lung, heart, spleen, diaphragm and femoral muscle were measured by inductively coupled plasma mass spectrometry (ICP-MS). Histological assessment was also conducted. Results: Tissue Gd deposition in all organs was significantly higher (P = 0.005 similar to 0.009) in the Gd-DTPA-BMA group than in the Gd-HP-DO3A and Gd-EOB-DTPA groups. In the Gd-DTPA-BMA group, Gd was predominantly deposited in kidney (1306 +/- 605.7 mu g/g), followed by skin, liver, lung, spleen, femoral muscle, diaphragm and heart. Comparing Gd-HP-DO3A and Gd-EOB-DTPA groups, Gd depositions in the kidney, liver and lung were significantly lower (P = 0.009 similar to 0.011) in the Gd-EOB-DTPA group than in the Gd-HP-DO3A group although no significant differences were seen for any other organs. Conclusions: Gd-EOB-DTPA is a stable and safe Gd-based contrast agent (GBCA) showing lower Gd deposition in major organs in renally impaired rats, compared with other GBCAs. This fact suggests that the risk of NSF onset would be low in the use of Gd-EOB-DTPA. (C) 2013 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available