Journal
MACROMOLECULAR CHEMISTRY AND PHYSICS
Volume 212, Issue 19, Pages 2173-2180Publisher
WILEY-V C H VERLAG GMBH
DOI: 10.1002/macp.201100303
Keywords
conducting polymers; conductivity; optical transmission; poly(3,4-ethylenedioxythiopnene) (PEDOT); thin films
Categories
Ask authors/readers for more resources
PEDOT is one of the most frequently studied conducting polymers in literature but values for optical transmission and electrical conductivity vary greatly. Therefore measurement protocols are examined and insights are suggested into why the protocols themselves may lead to differences. Reported PEDOT conductivity is the result of contact and non-contact film thickness and four-point probe measurements. The soft nature of PEDOT implies that any contact method must be executed with extreme care as values of conductivity ranging from 780 to 2 775 S.cm(-1) can be obtained. Similarly, variations in the optical minimum, maximum, and transmission range are found based on different switching voltage protocols. The results present here highlight the need for explicitly stating the measurement protocol used.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available