4.6 Article

Assessing the Accuracy of Contact Angle Measurements for Sessile Drops on Liquid-Repellent Surfaces

Journal

LANGMUIR
Volume 27, Issue 22, Pages 13582-13589

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/la2031208

Keywords

-

Funding

  1. Army Research Office (ARO) [W911NF-07-D-0004]
  2. Air Force Research Laboratory, Propulsion Directorate, Air Force Office of Scientific Research.

Ask authors/readers for more resources

Gravity-induced sagging can amplify variations in goniometric measurements of the contact angles of sessile drops on super-liquid-repellent surfaces. The very large value of the effective contact angle leads to increased optical noise in the drop profile near the solid-liquid free surface and the progressive failure of simple geometric approximations. We demonstrate a systematic approach to determining the effective contact angle of drops on super-repellent surfaces. We use a perturbation solution of the Bashforth-Adams equation to estimate the contact angles of sessile drops of water, ethylene glycol, and diiodomethane on an omniphobic surface using direct measurements of the maximum drop width and height. The results and analysis can be represented in terms of a dimensionless Bond number that depends on the maximum drop width and the capillary length of the liquid to quantify the extent of gravity-induced sagging. Finally, we illustrate the inherent sensitivity of goniometric contact angle measurement techniques to drop dimensions as the apparent contact angle approaches 180 degrees.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available