4.8 Article

Safety and performance of the drug-eluting absorbable metal scaffold (DREAMS) in patients with de-novo coronary lesions: 12 month results of the prospective, multicentre, first-in-man BIOSOLVE-I trial

Journal

LANCET
Volume 381, Issue 9869, Pages 836-844

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/S0140-6736(12)61765-6

Keywords

-

Funding

  1. Biotronik

Ask authors/readers for more resources

Background Bioabsorbable vascular scaffolds were developed to overcome limitations of permanent bare-metal or drug-eluting coronary stents-ie, stent thrombosis (despite prolonged dual antiplatelet therapy), the life-long presence of a caged vessel segment that does not allow vasomotion or remodelling, and chronic vessel wall inflammation. We assessed the safety and performance of a new magnesium-based paclitaxel-eluting absorbable metal scaff old in symptomatic patients with de-novo coronary lesions. Methods We did a prospective, multicentre, first-in-man trial (BIOSOLVE-1) of the drug-eluting absorbable metal scaff old (DREAMS). 46 patients with 47 lesions were enrolled at five European centres. The primary endpoint was target lesion failure, a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularisation, at 6 and 12 months. Clinical follow-up was scheduled at 1, 6, 12, 24, and 36 months. Patients were consecutively assigned to angiographic and intravascular ultrasonographic follow-up at 6 months or 12 months. Optical coherence tomography was done in some patients. All patients were recommended to take dual antiplatelet therapy for at least 12 months. This trial is registered with ClinicalTrials.gov, number NCT01168830. Findings Overall device and procedural success was 100%. Two of 46 (4%) patients had target lesion failure at 6 months (both clinically driven target lesion revascularisations), which rose to three of 43 (7%) at 12 months (one periprocedural target vessel myocardial infarction occurred during angiography at the 12 month follow-up visit). We noted no cardiac death or scaff old thrombosis. Interpretation Our results show feasibility, a good safety profile, and promising clinical and angiographic performance results up to 12 months for DREAMS. Our promising clinical results show that absorbable metal scaffolds might be an alternative to polymeric absorbable scaffolds.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available