4.6 Article

Computer-Aided Detection of Malignant Lung Nodutes on Chest Radiograpis: Effect on Observers' Performance

Journal

KOREAN JOURNAL OF RADIOLOGY
Volume 13, Issue 5, Pages 564-571

Publisher

KOREAN RADIOLOGICAL SOC
DOI: 10.3348/kjr.2012.13.5.564

Keywords

Computer-aided detection; Lung nodules; Lung cancer; Chest radiograph

Funding

  1. Industrial Strategic technology development program [10038419]
  2. Ministry of Knowledge Economy (MKE, Korea)
  3. Intelligent image diagnosis and therapy-support system

Ask authors/readers for more resources

Objective: To evaluate the effect of computer-aided detection (CAD) system on observer performance in the detection of malignant lung nodules on chest radiograph. Materials and Methods: Two hundred chest radiographs (100 normal and 100 abnormal with malignant solitary Lung nodules) were evaluated. With CT and histological confirmation serving as a reference, the mean nodule size was 15.4 mm (range, 7-20 mm). Five chest radiologists and five radiology residents independently interpreted both the original radiographs and CAD output images using the sequential testing method. The performances of the observers for the detection of malignant nodules with and without CAD were compared using the jackknife free-response receiver operating characteristic analysis. Results: Fifty-nine nodules were detected by the CAD system with a false positive rate of 1.9 nodules per case. The detection of malignant lung nodules significantly increased from 0.90 to 0.92 for a group of observers, excluding one first-year resident (p = 0.04). When lowering the confidence score was not allowed, the average figure of merit also increased from 0.90 to 0.91 (p = 0.04) for all observers after a CAD review. On average, the sensitivities with and without CAD were 87% and 84%, respectively; the false positive rates per case with and without CAD were 0.19 and 0.17, respectively. The number of additional malignancies detected following true positive CAD marks ranged from zero to seven for the various observers. Conclusion: The CAD system may help improve observer performance in detecting malignant lung nodules on chest radiographs and contribute to a decrease in missed Lung cancer.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available