4.1 Article

High-Performance Liquid Chromatographic Determination of Ustiloxin A in Forage Rice Silage

Journal

JOURNAL OF VETERINARY MEDICAL SCIENCE
Volume 71, Issue 2, Pages 239-241

Publisher

JAPAN SOC VET SCI
DOI: 10.1292/jvms.71.239

Keywords

Forage Rice; HPLC; Silage; Ustiloxin A

Funding

  1. Integrated Research Project for Developing a Japanese-style Forage Feeding System to Increase
  2. Ministry of Agriculture, Forestry and Fisheries of Japan

Ask authors/readers for more resources

We describe a high-performance liquid chromatographic method for determining ustiloxin A, a mycotoxin produced by Ustilaginoidea virens, in forage rice silage. Lyophilized silage samples were ground and extracted with water. The extracts were purified by solid-phase extraction and subjected to high-performance liquid chromatography using an octadecylsilane-bonded column. Separated ustiloxin A was detected with ultraviolet (UV) absorption at 254 nm. The limit of quantitation for ustiloxin A in silage found to be 2.5 mg/kg. The present method can be Used for routine monitoring of the contamination of ustiloxin A in forage rice silage.