4.2 Article

Self-expanding foam for prehospital treatment of intra-abdominal hemorrhage: 28-day survival and safety

Journal

JOURNAL OF TRAUMA AND ACUTE CARE SURGERY
Volume 77, Issue -, Pages S127-S133

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/TA.0000000000000380

Keywords

Noncompressible; abdominal hemorrhage; survival; safety; swine

Funding

  1. DARPA
  2. ARO [W911NF-10-C-0089, W911NF-12-C-0066]

Ask authors/readers for more resources

BACKGROUND: Intracavitary noncompressible hemorrhage remains a significant cause of preventable death on the battlefield and in the homeland. We previously demonstrated the hemostatic efficacy of an in situ self-expanding poly(urea) urethane foam in a severe, closed-cavity, hepatoportal exsanguination model in swine. We hypothesized that treatment with, and subsequent explantation of, foam would not adversely impact 28-day survival in swine. METHODS: Following a closed-cavity splenic transection, animals received either fluid resuscitation alone (control group, n = 6) or resuscitation plus foam treatment at doses of 100 mL (n = 6), 120 mL (n = 6), and 150 mL (n = 2). Foam was allowed to polymerize in situ and was explanted after 3 hours. The animals were recovered and monitored for 28 days. RESULTS: All 18 animals in the 100-mL, 120-mL, and control groups survived to the 28-day endpoint without complications. The 150-mL group was terminated after the acute phase (n = 2). En bloc explantation of the foam took less than 2 minutes and was associated with millimeter-sized remnant particles. All foam animals required some level of enteric repair (imbrication or resection). Excluding the aborted 150-mL group, all animals survived, with no differences in renal or hepatic function, serum chemistries, or semiquantitative abdominal adhesion scores. Histologic analysis demonstrated that remnant particles were associated with a fibrotic capsule and mild inflammation, similar to that of standard suture reaction. In addition, safety testing(including genotoxicity, pyrogenicity, and cytotoxicity) was performed consistent with the ISO-10993 standard, and the materials passed all tests. CONCLUSION: For a distinct dose range, 28-day recovery after foam treatment and explantation for noncompressible, intra-abdominal hemorrhage is not associated with significant physiologic or biochemical evidence of end-organ dysfunction. A foam volume exceeding the maximum tolerable dose was identified. Bowel repair is required to ensure survival. (Copyright (C) 2014 by Lippincott Williams & Wilkins)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available