Objectives: The present systematic review objectively assessed the safety and clinical effectiveness of trans-catheter aortic valve implantation for patients at high surgical risk with severe aortic stenosis. Methods: Electronic searches were performed in 6 databases from January 2000 to March 2009. The end points included feasibility, safety, efficacy, and durability. Clinical effectiveness was synthesized through a narrative review with full tabulation of results of all included studies. Results: The current evidence on transcatheter aortic valve implantation for aortic stenosis is limited to short-term observational studies. The overall procedural success rates ranged from 74% to 100%. The incidence of major adverse events included 30-day mortality (0%-25%), major ventricular tachyarrhythmia (0%-4%), myocardial infarction (0%-15%), cardiac tamponade (2%-10%), stroke (0%-10%), conversion to surgery (0%-8%), moderate to major paravalvular leak (4%-35%), vascular complication (8%-17%), valve-in-valve procedure (2%-12%), and aortic dissection/ perforation (0%-4%). The overall 30-day major adverse cardiovascular and cerebral events ranged from 3% to 35%. The mean aortic valve area ranged from 0.5 to 0.8 cm 2 before and 1.3 to 2.0 cm(2) after transcatheter aortic valve implantation. The mean pressure gradient ranged from 34 to 58 mm Hg before and 3 to 12 mm Hg after transcatheter aortic valve implantation. There was no significant deterioration in echocardiography measurements during the assessment period. Death rate at 6 months postprocedure ranged from 18% to 48%. No studies had adequate follow-up to reliably evaluate long-term outcomes. Conclusions: The procedure has a potential for serious complications. Although short-term efficacy based on echocardiography measurements is good, there is little evidence on long-term outcomes. The use of transcatheter aortic valve implantation should be considered only within the boundaries of clinical trials. (J Thorac Cardiovasc Surg 2010;139:1519-28)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available