4.4 Article

A Fitting Formula for Predicting Droplet Mean Diameter for Various Liquid in Effervescent Atomization Spray

Journal

JOURNAL OF THERMAL SPRAY TECHNOLOGY
Volume 19, Issue 3, Pages 586-601

Publisher

SPRINGER
DOI: 10.1007/s11666-009-9457-4

Keywords

effervescent atomization spray; fitting formula; liquid physical property; operating conditions

Funding

  1. National Natural Science Foundation of China [10632070, 10602052]

Ask authors/readers for more resources

The outflow of the effervescent atomization spray is simulated by a comprehensive numerical model based on the Navier-Stokes equation and the particle tracking method. The droplet mean diameter under different operating conditions and liquid properties were calculated. Based on the extensive computations, a formula relating droplet Sauter mean diameter to the operating conditions and liquid physical parameters were obtained with curve fitting technique. The results calculated from the formulae were compared with the experimental data and a good agreement was obtained. The formulae can be used to predict the droplet mean diameter for various Newtonian liquid in axisymmetric effervescent atomization spray conveniently and effectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available