4.6 Article

Abuse by External Heating, Overcharge and Short Circuiting of Commercial Lithium-Ion Battery Cells

Journal

JOURNAL OF THE ELECTROCHEMICAL SOCIETY
Volume 161, Issue 10, Pages A1611-A1617

Publisher

ELECTROCHEMICAL SOC INC
DOI: 10.1149/2.0311410jes

Keywords

-

Funding

  1. Swedish Energy Agency
  2. FFI-program

Ask authors/readers for more resources

Lithium-ion batteries offer great energy and power densities but the thermal stability is an issue of concern compared to other battery technologies. In this study different types of abuse testing have been performed in order to compare the battery safety for different types of commercial lithium-ion battery cells. The results show large differences in abuse response for different cells. Exposed to external heating laptop cells with cobalt based cathode developed a thermal runaway resulting in pressure release, fire. and temperatures over 700 degrees C. Lithium iron phosphate (LFP) is known to be a very thermally stable cathode material and LFP-cells showed a significantly lower thermal response, a thermal runaway could, however, be detected for some of the cells in the external heating test. The overcharge tests of LFP-cells were in most cases uneventful but in one case the test resulted in a violent fire. The short circuit tests showed modest temperature increases of the cells in spite of high currents peaking at around 1000 A. Although the development of safer lithium-ion battery cells has been successful thermal runaway events may still occur under extreme conditions. (C) 2014 The Electrochemical Society. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available