4.5 Article

Interpretation of Remotely Downloaded Pocket-Size Cardiac Ultrasound Images on a Web-Enabled Smartphone: Validation Against Workstation Evaluation

Journal

JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY
Volume 24, Issue 12, Pages 1325-1330

Publisher

MOSBY-ELSEVIER
DOI: 10.1016/j.echo.2011.08.007

Keywords

Echocardiography; Pocket-size ultrasound; Telemedicine

Funding

  1. Richard B. and Lynne V. Cheney Cardiovascular Institute, George Washington University (Washington, DC)

Ask authors/readers for more resources

Background: Pocket-size ultrasound has increased echocardiographic portability, but expert point-of-care interpretation may not be readily available. The aim of this study was to test the hypothesis that remote interpretation on a smartphone with dedicated medical imaging software can be as accurate as on a workstation. Methods: Eighty-nine patients in a remote Honduran village underwent echocardiography by a nonexpert using a pocket-size ultrasound device. Images were sent for verification of point-of-care diagnosis to two expert echocardiographers in the United States reading on a workstation. Studies were then anonymized, randomly ordered, and reinterpreted on a smartphone with a dedicated, Health Insurance Portability and Accountability Act-compliant application. Point-of-care diagnosis was considered accurate if any abnormal finding was matched and categorized at the same level of severity (mild, moderate, or severe) by either expert interpretation. Results: The mean age was 54 +/- 23 years, and 57% of patients were women. The most common indications for echocardiography were arrhythmia (33%), cardiomyopathy (28%), and syncope (15%). Using the workstation, point-of-care diagnoses were changed in 38% of cases by expert overread (41% left ventricular function correction, 38% valvulopathy correction, 18% poor image quality). Expert interobserver agreement was excellent at 82%, with a Cohen's kappa value of 0.82 (95% confidence interval, 0.70-0.94). Intraobserver agreement comparing interpretations on workstations and smartphones was 90%, with a Cohen's kappa value of 0.86 (95% confidence interval, 0.76-0.97), signifying excellent intertechnology agreement. Conclusions: Remote expert echocardiographic interpretation can provide backup support to point-of-care diagnosis by nonexperts when read on a dedicated smartphone-based application. Mobile-to-mobile consultation may improve access in previously inaccessible locations to accurate echocardiographic interpretation by experienced cardiologists. (J Am Soc Echocardiogr 2011;24:1325-30.)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available