4.5 Article

Feasibility and Accuracy of Different Techniques of Two-Dimensional Speckle Based Strain and Validation With Harmonic Phase Magnetic Resonance Imaging

Journal

JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY
Volume 21, Issue 12, Pages 1318-1325

Publisher

MOSBY-ELSEVIER
DOI: 10.1016/j.echo.2008.09.021

Keywords

Myocardial strain; Doppler tissue imaging; Regional myocardial function; Left ventricular function

Funding

  1. National Health and Medical Research Council of Australia, Canberra, Australia [210218]
  2. GE Medical Systems (Milwaukee, WI)
  3. Siemens Medical Solutions (Mountain View, CA)

Ask authors/readers for more resources

Background: Different 2-dimensional speckle-based strain techniques have been developed to overcome the problem of angle dependency with Doppler-based strain. However, their relative accuracy has not been assessed. The aim of this study was to determine the feasibility and accuracy of 2 such techniques (velocity vector imaging [VVI] and automated function imaging [AFI]), using tagged harmonic phase (HARP) magnetic resonance imaging (MRI) as a reference standard. Methods: Thirty patients with known or suspected ischemic heart disease underwent measurement of peak systolic longitudinal, radial, and circumferential Lagrangian strain with all 3 techniques using a 16-segment model. The extent of scar tissue in each segment was determined using contrast-enhanced MRI. Results: The measurement of myocardial strain in all 3 directions was highly feasible with both VVI and AFI. Longitudinal strain was underestimated by both VVI (-11 +/- 8%; P < .01) and AFI (-12 +/- 6%; P < .01) in comparison with HARP MRI (-14 +/- 5%), and radial strain was underestimated by VVI (14 +/- 18% vs 23 +/- 7%; P < .01). All strain measurements with AFI showed better correlation and agreement with HARP MRI compared with VVI. Circumferential strain with AFI had the greatest accuracy (area under the receiver operating characteristic curve = 0.74, P < .001) for the prediction of scar tissue on MRI. Conclusions: Two-dimensional strain measured with AFI has significantly better accuracy than VVI. Circumferential strain with AFI has the best discriminative ability for the detection of regional myocardial dysfunction. (J Am Soc Echocardiogr 2008; 21: 1318-1325.)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available