4.7 Article

Laboratory Measurement of the Anticoagulant Activity of the Non-Vitamin K Oral Anticoagulants

Journal

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
Volume 64, Issue 11, Pages 1128-1139

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2014.05.065

Keywords

apixaban; dabigatran; laboratory; monitoring; rivaroxaban

Funding

  1. National Heart, Lung, and Blood Institute [HL112903]
  2. Diagnostica Stago
  3. Boehringer Ingelheim
  4. Portola
  5. Viropharm
  6. AKP America
  7. Leo Pharma (McMaster University)
  8. Bayer
  9. Celgene
  10. Shire
  11. CSL Behring

Ask authors/readers for more resources

BACKGROUND Non-vitamin K oral anticoagulants (NOACs) do not require routine laboratory monitoring. However, laboratory measurement may be desirable in special situations and populations. OBJECTIVES This study's objective was to systematically review and summarize current evidence regarding laboratory measurement of the anticoagulant activity of dabigatran, rivaroxaban, and apixaban. METHODS We searched PubMed and Web of Science for studies that reported a relationship between drug levels of dabigatran, rivaroxaban, and apixaban and coagulation assay results. Study quality was evaluated using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2). RESULTS We identified 17 eligible studies for dabigatran, 15 for rivaroxaban, and 4 for apixaban. For dabigatran, a normal thrombin time excludes clinically relevant drug concentrations. The activated partial thromboplastin time (APTT) and prothrombin time (PT) are less sensitive and may be normal at trough drug levels. The dilute thrombin time (R-2 = 0.92 to 0.99) and ecarin-based assays (R-2 = 0.92 to 1.00) show excellent linearity across on-therapy drug concentrations and may be used for drug quantification. For rivaroxaban and apixaban, anti-Xa activity is linear (R-2 = 0.89 to 1.00) over a wide range of drug levels and may be used for drug quantification. Undetectable anti-Xa activity likely excludes clinically relevant drug concentrations. The PT is less sensitive (especially for apixaban); a normal PT may not exclude clinically relevant levels. The APTT demonstrates insufficient sensitivity and linearity for quantification. CONCLUSIONS Dabigatran, rivaroxaban, and apixaban exhibit variable effects on coagulation assays. Understanding these effects facilitates interpretation of test results in NOAC-treated patients. More information on the relationship between drug levels and clinical outcomes is needed. (c) 2014 by the American College of Cardiology Foundation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available