4.7 Article

Percutaneous Mitral Valve Repair for Mitral Regurgitation in High-Risk Patients Results of the EVEREST II Study

Journal

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
Volume 64, Issue 2, Pages 172-181

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2013.12.062

Keywords

high surgical risk; mitral valve insufficiency; percutaneous

Funding

  1. Abbott
  2. Medtronic
  3. Baxter
  4. ValTech Cardio
  5. Guided Delivery Systems
  6. Tendyne
  7. Bracco Diagnostics
  8. Boston Scientific
  9. Cordis
  10. Eli Lilly
  11. Daiichi-Sankyo
  12. Bristol-Myers Squibb
  13. Sanofi-Aventis
  14. Edwards Lifesciences

Ask authors/readers for more resources

BACKGROUND The EVEREST II (Endovascular Valve Edge-to-Edge REpair STudy) High-Risk registry and REALISM Continued Access Study High-Risk Arm are prospective registries of patients who received the MitraClip device (Abbott Vascular, Santa Clara, California) for mitral regurgitation (MR) in the United States. OBJECTIVES The purpose of this study was to report 12-month outcomes in high-risk patients treated with the percutaneous mitral valve edge-to-edge repair. METHODS Patients with grades 3 to 4+ MR and a surgical mortality risk of >= 12%, based on the Society of Thoracic Surgeons risk calculator or the estimate of a surgeon coinvestigator following pre-specified protocol criteria, were enrolled. RESULTS In the studies, 327 of 351 patients completed 12 months of follow-up. Patients were elderly (76 +/- 11 years of age), with 70% having functional MR and 60% having prior cardiac surgery. The mitral valve device reduced MR to <= 2+ in 86% of patients at discharge (n = 325; p < 0.0001). Major adverse events at 30 days included death in 4.8%, myocardial infarction in 1.1%, and stroke in 2.6%. At 12 months, MR was <= 2+ in 84% of patients (n = 225; p < 0.0001). From baseline to 12 months, left ventricular (LV) end-diastolic volume improved from 161 +/- 56 ml to 143 +/- 53 ml (n = 203; p < 0.0001) and LV end-systolic volume improved from 87 +/- 47 ml to 79 +/- 44 ml (n = 202; p < 0.0001). New York Heart Association functional class improved from 82% in class III/IV at baseline to 83% in class I/II at 12 months (n = 234; p < 0.0001). The 36-item Short Form Health Survey physical and mental quality-of-life scores improved from baseline to 12 months (n = 191; p < 0.0001). Annual hospitalization rate for heart failure fell from 0.79% pre-procedure to 0.41% post-procedure (n = 338; p < 0.0001). Kaplan-Meier survival estimate at 12 months was 77.2%. CONCLUSIONS The percutaneous mitral valve device significantly reduced MR, improved clinical symptoms, and decreased LV dimensions at 12 months in this high-surgical-risk cohort. (C) 2014 by the American College of Cardiology Foundation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available