4.7 Article

Clinical Outcomes After Transcatheter Aortic Valve Replacement Using Valve Academic Research Consortium Definitions A Weighted Meta-Analysis of 3,519 Patients From 16 Studies

Journal

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
Volume 59, Issue 25, Pages 2317-2326

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2012.02.022

Keywords

aortic stenosis; TAVI; TAVR; VARC

Funding

  1. Edwards Lifesciences
  2. St. Jude Medical
  3. Medtronic Vascular

Ask authors/readers for more resources

Objectives This study sought to perform a weighted meta-analysis to determine the rates of major outcomes after transcatheter aortic valve replacement (TAVR) using Valve Academic Research Consortium (VARC) definitions and to evaluate their current use in the literature. Background Recently, the published VARC definitions have helped to add uniformity to reporting outcomes after TAVR. Methods A comprehensive search of multiple electronic databases from January 1, 2011, through October 12, 2011, was conducted using predefined criteria. We included studies reporting at least 1 outcome using VARC definitions. Results A total of 16 studies including 3,519 patients met inclusion criteria and were included in the analysis. The pooled estimate rates of outcomes were determined according to VARC's definitions: device success, 92.1% (95% confidence interval [CI]: 88.7% to 95.5%); all-cause 30-day mortality, 7.8% (95% CI: 5.5% to 11.1%); myocardial infarction, 1.1% (95% CI: 0.2% to 2.0%); acute kidney injury stage II/III, 7.5% (95% CI: 5.1% to 11.4%); life-threatening bleeding, 15.6% (95% CI: 11.7% to 20.7%); major vascular complications, 11.9% (95% CI: 8.6% to 16.4%); major stroke, 3.2% (95% CI: 2.1% to 4.8%); and new permanent pacemaker implantation, 13.9% (95% CI: 10.6% to 18.9%). Medtronic CoreValve prosthesis use was associated with a significant higher rate of new permanent pacemaker implantation compared with the Edwards prosthesis (28.9% [95% CI: 23.0% to 36.0%] vs. 4.9% [95% CI: 3.9% to 6.2%], p < 0.0001). The 30-day safety composite endpoint rate was 32.7% (95% CI: 27.5% to 38.8%) and the 1-year total mortality rate was 22.1% (95% CI: 17.9% to 26.9%). Conclusions VARC definitions have already been used by the TAVR clinical research community, establishing a new standard for reporting clinical outcomes. Future revisions of the VARC definitions are needed based on evolving TAVR clinical experiences. (J Am Coll Cardiol 2012;59:2317-26) (C) 2012 by the American College of Cardiology Foundation

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available