4.7 Article

Myocardial Oxygenation in Coronary Artery Disease Insights From Blood Oxygen Level-Dependent Magnetic Resonance Imaging at 3 Tesla

Journal

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
Volume 59, Issue 22, Pages 1954-1964

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2012.01.055

Keywords

blood oxygen level-dependent; ischemia; myocardial blood flow

Funding

  1. British Heart Foundation
  2. UK Medical Research Council
  3. Oxford Partnership Comprehensive Biomedical Research Centre
  4. Department of Health's NIHR Biomedical Research Center
  5. MRC [G0700796, G0900883] Funding Source: UKRI
  6. Medical Research Council [G0700796, G0900883] Funding Source: researchfish

Ask authors/readers for more resources

Objectives The purpose of this study was to assess the diagnostic accuracy of blood oxygen-level dependent (BOLD) MRI in suspected coronary artery disease (CAD). Background By exploiting the paramagnetic properties of deoxyhemoglobin, BOLD magnetic resonance imaging can detect myocardial ischemia. We applied BOLD imaging and first-pass perfusion techniques to: 1) examine the pathophysiological relationship between coronary stenosis, perfusion, ventricular scar, and myocardial oxygenation; and 2) evaluate the diagnostic performance of BOLD imaging in the clinical setting. Methods BOLD and first-pass perfusion images were acquired at rest and stress (4 to 5 min intravenous adenosine, 140 mu g/kg/min) and assessed quantitatively (using a BOLD signal intensity index [stress/resting signal intensity], and absolute quantification of perfusion by model-independent deconvolution). A BOLD signal intensity index threshold to identify ischemic myocardium was first determined in a derivation arm (25 CAD patients and 20 healthy volunteers). To determine diagnostic performance, this was then applied in a separate group comprising 60 patients with suspected CAD referred for diagnostic angiography. Results Prospective evaluation of BOLD imaging yielded an accuracy of 84%, a sensitivity of 92%, and a specificity of 72% for detecting myocardial ischemia and 86%, 92%, and 72%, respectively, for identifying significant coronary stenosis. Segment-based analysis revealed evidence of dissociation between oxygenation and perfusion (r = -0.26), with a weaker correlation of quantitative coronary angiography with myocardial oxygenation (r = -0.20) than with perfusion (r = -0.40; p = 0.005 for difference). Hypertension increased the odds of an abnormal BOLD response, but diabetes mellitus, hypercholesterolemia, and the presence of ventricular scar were not associated with significant deoxygenation. Conclusions BOLD imaging provides valuable insights into the pathophysiology of CAD; myocardial hypoperfusion is not necessarily commensurate with deoxygenation. In the clinical setting, BOLD imaging achieves favorable accuracy for identifying the anatomic and functional significance of CAD. (J Am Coll Cardiol 2012; 59: 1954-64) (C) 2012 by the American College of Cardiology Foundation

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available