Objectives The goal of this study was to evaluate the ability of noninvasive programmed stimulation (NIPS) after ventricular tachycardia (VT) ablation to identify patients at high risk of recurrence. Background Optimal endpoints for VT ablation are not well defined. Methods Of 200 consecutive patients with VT and structural heart disease undergoing ablation, 11 had clinical VT inducible at the end of ablation and 11 recurred spontaneously. Of the remaining 178 patients, 132 underwent NIPS through their implantable cardioverter-defibrillator 3.1 +/- 2.1 days after ablation. At 2 drive cycle lengths, single, double, and triple right ventricular extrastimuli were delivered to refractoriness. Clinical VT was defined by comparison with 12-lead electrocardiograms and stored implantable cardioverter-defibrillator electrograms from spontaneous VT episodes. Patients were followed for 1 year. Results Fifty-nine patients (44.7%) had no VT inducible at NIPS; 49 (37.1%) had inducible nonclinical VT only; and 24 (18.2%) had inducible clinical VT. Patients with inducible clinical VT at NIPS had markedly decreased 1-year VT-free survival compared to those in whom no VT was inducible (<30% vs. >80%; p = 0.001), including 33% recurring with VT storm. Patients with inducible nonclinical VT only, had intermediate 1-year VT-free survival (65%). Conclusions When patients with VT and structural heart disease have no VT or nonclinical VT only inducible at the end of ablation or their condition is too unstable to undergo final programmed stimulation, NIPS should be considered in the following days to further define risk of recurrence. If clinical VT is inducible at NIPS, repeat ablation may be considered because recurrence over the following year is high. (J Am Coll Cardiol 2012;59:1529-35) (C) 2012 by the American College of Cardiology Foundation

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available