4.7 Article

Action Potential Dynamics Explain Arrhythmic Vulnerability in Human Heart Failure

Journal

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
Volume 52, Issue 22, Pages 1782-1792

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2008.08.037

Keywords

calcium cycling; electrical restitution; ventricular action potentials; computer modeling; conduction velocity; T-wave alternans; sudden cardiac arrest

Funding

  1. NHLBI NIH HHS [HL83359, R01 HL082729, R01 HL063195, R01 HL083359, R01 HL067322, HL063195, HL082729, K23 HL070529-05, HL70529, K23 HL070529-01, HL067322, R01 HL083359-01A1, K23 HL070529-02, K23 HL070529, K23 HL070529-04, K23 HL070529-03] Funding Source: Medline

Ask authors/readers for more resources

Objectives The purpose of this study was to determine whether abnormalities of calcium cycling explain ventricular action potential (AP) oscillations and cause electrocardiogram T-wave alternans (TWA). Background Mechanisms explaining why heart failure patients are at risk for malignant ventricular arrhythmias (ventricular tachycardia [VT]/ventricular fibrillation [VF]) are unclear. We studied whether oscillations in human ventricular AP explain TWA and predict VT/VF, and used computer modeling to suggest potential cellular mechanisms. Methods We studied 53 patients with left ventricular ejection fraction 28 +/- 8% and 18 control subjects. Monophasic APs were recorded in the right ventricle (n = 62) and/or left ventricle (n = 9) at 109 beats/min. Results Alternans of AP amplitude, computed spectrally, had higher magnitude in study patients than in controls (p = 0.03), particularly in AP phase II (p = 0.02) rather than phase III ( p = 0.10). The AP duration and activation restitution (n = 11 patients) were flat at 109 beats/min and did not explain TWA. In computer simulations, only reduced sarcoplasmic reticulum calcium uptake explained our results, causing calcium oscillations, AP amplitude alternans, and TWA that were all abolished by calcium clamping. On prospective follow-up for 949 +/- 553 days, 17 patients had VT/VF. The AP amplitude alternans predicted VT/VF ( p = 0.04), and was 78% concordant with simultaneous TWA ( p = 0.003). Conclusions Patients with systolic dysfunction show ventricular AP amplitude alternans that prospectively predicted VT/VF. Alternans in AP amplitude, but not variations in AP duration or conduction, explained TWA at <= 109 beats/min. In computer models, these findings were best explained by reduced sarcoplasmic reticulum calcium uptake. Thus, in heart failure patients, in vivo AP alternans may reflect cellular calcium abnormalities and provide a mechanistic link with VT/VF. (J Am Coll Cardiol 2008; 52: 1782-92) (c) 2008 by the American College of Cardiology Foundation

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available