4.7 Article

Conduit artery constriction mediated by low flow - A novel noninvasive method for the assessment of vascular function

Journal

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
Volume 51, Issue 20, Pages 1953-1958

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2008.01.049

Keywords

-

Ask authors/readers for more resources

Objectives We describe and validate a novel noninvasive method that complements the data from traditional flow-mediated dilation (FMD) studies. Background The study of peripheral vascular reactivity provides important diagnostic and prognostic information in patients with (or at risk for) cardiovascular disease. Methods High-resolution ultrasound and automatic computerized analysis were used to measure the diameter of the radial artery at rest and in conditions of locally decreased and increased shear stress (respectively, low-flow-mediated constriction [L-FMC] and flow-mediated dilation [FMD]). A composite end point (L-FMC + FMD) was also calculated. A total of 196 studies were performed. Results When the repeatability of the method was tested, the range of variation across measurements was 1.1% for L-FMC and 1.7% for FMD; the intraclass correlation coefficient was 0.80 and 0.68, respectively. Low-flow-mediated constriction, FMD, and their composite end point were significantly blunted after acute smoking, in coronary artery disease patients, and in hypertensive patients as compared with that seen in healthy age-matched volunteers (p < 0.01, analysis of variance). Low-flow-mediated constriction, but not FMD, was blunted (p < 0.05) after administration of fluconazole (an inhibitor of a cytochrome P450-derived endothelium-derived hyperpolarization factor) and aspirin (an inhibitor of cyclooxygenase). Flow-mediated dilation, but not L-FMC, was blunted (p < 0.05) by nitric oxide synthase inhibition. Conclusions Low-flow-mediated constriction is a simple, rapid, and accurate measure of resting arterial tone that does not require further procedures as compared with traditional FMD measurements. While FMD measures endothelial responses to sudden increases in shear stress, L-FMC is a measure of the response to resting shear stress levels, and, therefore, it provides additional information that is complementary to FMD.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available