Background: Large volumes of dilute local anesthesia are increasingly used not only for liposuction but also for other large cutaneous surgeries, including skin cancer excision. Although the lidocaine serum levels and peaks after injection of tumescent anesthesia in the trunk were shown to be safe even when used in high doses, the levels after use of less dilute (1% lidocaine) solutions for facial cancer surgery have not been described. Objective: We sought to ascertain whether perioperative peak lidocaine levels during Mobs micrographic surgery approach thresholds for lidocaine toxicity. Methods: In this prospective cohort study, each Molls micrographic procedure was commenced per routine protocol, with use of injectable 1% lidocaine with 1:200,000 epinephrine and 1:10 8.4% bicarbonate for local anesthesia. Six peripheral blood draws of 5 mL each were performed and sent for serum lidocaine concentration measurement. Blood draws were obtained before and after the first two stages of Mohs micrographic surgery, and before and after the third stage or wound repair, as appropriate. Subjects and investigators reported any symptoms or signs of lidocaine toxicity. The main outcome measures include: (I) number of subjects exhibiting at least one level higher than the threshold for toxicity; and (2) sustained elevated lidocaine levels in one or more subjects. Results: Mean total lidocaine volume per subject was 15 mL (range: 5-48 mL). The highest peak serum lidocaine level detected at any time point (blood draw) for any subject was 0.3 mu g/mL. Mean serum lidocaine level for all 6 time points was less than 0.1 mu g/mL and was thus not detected. Detectable lidocaine levels were found to be associated with higher mean (P = .028) and median (P = .008) total lidocaine doses. Because no toxic levels were detected, it was not possible to measure sustained high lidocaine levels. Limitations: Limitations of this study include the lack of use of very concentrated (eg, 2% vs 1%) lidocaine solution. Conclusions: Lidocaine use during Mohs micrographic surgery does not appear to result in serum lidocaine levels approaching toxic levels even when relatively high total lidocaine doses are used. There is an association between higher total lidocaine dose and perioperative peak serum lidocaine level. (J Am Acad Dermatol 2010;63:87-92.)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available