Ask authors/readers for more resources
The paper addresses the chemical purification behavior of detonation nanodiamond soot in the case of using a dilute nitric acid under pressure. The optimal process is found to proceed at 230-240C, 7-8 MPa, with HNO3 excess of 200-300% of stoichiometry.