4.5 Article

Measurements of the flow of supercritical carbon dioxide through short orifices

Journal

JOURNAL OF SUPERCRITICAL FLUIDS
Volume 88, Issue -, Pages 17-25

Publisher

ELSEVIER
DOI: 10.1016/j.supflu.2014.01.008

Keywords

Supercritical carbon dioxide; Orifice; Two-phase flow; Discharge coefficient; Critical flow; Choked flow

Funding

  1. U.S. Department of Energy Nuclear Energy University Programs [11-1625]

Ask authors/readers for more resources

This paper describes the methods used to measure flow rate of supercritical and two-phase CO2 through short orifices. Orifices with diameters of 1 millimeter and orifice length-to-diameter ratios of 3.2 and 5 were tested. Flow rates through these orifices were measured over a broad range of inlet conditions in the supercritical region with orifice inlet pressures ranging from 5 MPa to 11 MPa and inlet densities ranging from 86.5 kg/m(3) to 630 kg/m(3). The data were compared to the isentropic real gas model for expansion of a fluid through a nozzle in order to observe the behavior of the discharge coefficient. For a given orifice inlet condition, the single-phase discharge coefficient was found to be between 0.81 and 0.87 and was independent of the pressure ratio. The discharge coefficient increased as the pressure ratio decreased when two-phase CO2 was present with orifice inlet pressures of 7.7 MPa and 9 MPa. The critical mass flow rate and critical pressure ratio were determined for each test. The raw data from this investigation are available on the internet. This paper describes the methods used to measure flow of supercritical and two-phase CO2 through short orifices. Orifices with diameters of 1 millimeter and orifice length-to-diameter ratios of 3.2 and 5 were tested. Flow rates through these orifices were measured over a broad range of inlet conditions in the supercritical region with orifice inlet pressures ranging from 7.7 MPa to 11 MPa and inlet densities ranging from 111 kg/m(3) to 630 kg/m(3). The data were compared to the isentropic real gas model for expansion of a fluid through a nozzle in order to observe the behavior of the discharge coefficient. For a given orifice inlet condition, the single-phase discharge coefficient was found to be between 0.81 and 0.87 and was independent of the pressure ratio. The discharge coefficient increased as the pressure ratio decreased when two-phase CO2 was present with orifice inlet pressures of 7.7 MPa and 9 MPa. The critical mass flow rate and critical pressure ratio were determined for each test. The raw data from this investigation are available on the internet. Published by Elsevier B.V.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available